Instrument list

Canon Fundus Photography

Specific Instrument CF-1 mydriatic and CR-1 non-mydriatic fundus cameras
Measures/Output En face colour fundus images
Sample clinical use Stereoscopic viewing of the optic nerve head, imaging of retinal and choroidal pathology
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Confoscan Corneal Assessment

Specific Instrument Nidek Confoscan 4
Measures/Output En face confocal microscopy of the cornea with up to 500x magnification
Sample clinical use Epithelial/total corneal thickness, corneal substructure and morphology, endothelial cell count
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Diagnosys Electrophysiology Suite

Specific Instrument Diagnosys
Measures/Output Electrophysiological assessment of the retina (ERG) and visual pathways (VEP) using full-field
and multifocal stimulation
Sample clinical use Retinal dystrophies, visual pathway lesions
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

GDx Scanning Laser Polarimetry

Specific Instrument GDx Pro
Measures/Output Peripapillary retinal nerve fibre layer thickness with ECC and VCC options
Sample clinical use Glaucoma, optic neuropathies
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Haag-Streit Digital Goldmann Tonometry

Specific Instrument AT 900D
Measures/Output Goldmann tonometry to 0.5mmHg with digital output
Sample clinical use Intraocular pressure measurement
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Haag-Streit Optical Biometry Using Partial Coherence Interferometry

Specific Instrument Lensstar
Measures/Output Axial length, corneal thickness, anterior chamber depth, crystalline lens thickness, vitreous
chamber depth, retinal thickness, IOL power
Sample clinical use Assessment for cataract surgery, glaucoma, myopia progression
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Haag-Streit Pachymetry

Specific Instrument Haag-Streit OLCR pachymeter
Measures/Output Corneal thickness to one micrometer accuracy using an interferometry technique
Sample clinical use Central corneal thickness
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Haag-Streit Video Slit Lamp Imaging

Specific Instrument Haag-Streit BQ 900 video slit lamps and Haag-Streit BX photographic slit lamp
Measures/Output Video and still digital imaging of the anterior segment
Sample clinical use Imaging pathology of the anterior segment of the eye
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Heidelberg HRT3 Corneal Assessment

Specific Instrument HRT III with Rostock Cornea Module
Measures/Output En face confocal microscopy of the cornea
Sample clinical use Epithelial/total corneal thickness, corneal substructure and morphology, endothelial cell count
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Heidelberg HRT3 Glaucoma Assessment

Specific Instrument HRT III with glaucoma module
Measures/Output Confocal microscopy of the optic nerve head, optic nerve head morphology, peripapillary
retinal nerve fibre layer thickness
Sample clinical use Glaucoma, optic neuropathies
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Heidelberg Optical Coherence Tomography

Specific Instrument Spectralis OCT
Measures/Output Retinal/macula/optic nerve head cross-section and morphology, macular thickness,
peripapillary retinal nerve fibre layer thickness, fundus auto-fluorescence
Sample clinical use Age-related macular degeneration, diabetic retinopathy, glaucoma, retinal dystrophies
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Humphrey Visual Field Analysis

Specific Instrument HFA Model 750
Measures/Output Sensitivity of the visual field using white-on-white or blue/yellow stimuli plus GPA analysis
Sample clinical use Glaucoma assessment, pathology of the anterior and posterior visual pathways
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Humphrey Matrix Perimetry

Specific Instrument Matrix
Measures/Output Sensitivity of the visual field using frequency-doubling stimuli
Sample clinical use Glaucoma assessment, pathology of the anterior and posterior visual pathways
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

iCare Tonometer

Specific Instrument iCare rebound tonometer
Measures/Output Intraocular pressure measurement without corneal anaesthesia
Sample clinical use Glaucoma assessment
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

ImagineEyes Wavefront Aberrometry

Specific Instrument IRX3
Measures/Output Total eye refractive aberrations expressed in Zernike coefficients, modulation transfer and
point spread function, Strehl ratio
Sample clinical use Assessment for, and post-operative management of, refractive/cataract surgery, keratoconus
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Keeler Wireless Binocular Indirect Ophthalmoscopy

Specific Instrument Keeler Vantage wireless and video LED binocular indirect ophthalmoscopes
Measures/Output Imaging of the posterior eye and ability to record results using video technology
Sample clinical use Assessment of the retina
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Medmont Corneal Topography

Specific Instrument E300
Measures/Output Corneal topography and curvature variations across the corneal surface
Sample clinical use Keratoconus, corneal graft, pterygium
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Oculus Pentacam Scheimpflug Photography

Specific Instrument Pentacam HR
Measures/Output Anterior chamber cross section and volumetric assessment, total corneal pachymetry, corneal
aberration analysis, crystalline lens densitometry
Sample clinical use Keratoconus, corneal dystrophies, glaucoma assessment, cataract surgery assessment
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Optomap Wide-Field Fundus Photography

Specific Instrument Optomap P20MA
Measures/Output Wide-field fundus photography
Sample clinical use Diabetic retinopathy, peripheral retinal disorders, choroidal nevi/melanoma
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Optovue Optical Coherence Tomography

Specific Instrument Optovue
Measures/Output Anterior segment/retinal/macula/optic nerve head cross-section and morphology, macular
thickness, peripapillary retinal nerve fibre layer thickness
Sample clinical use Lasik, keratoconus, age-related macular degeneration, diabetic retinopathy, glaucoma,
retinal dystrophies
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Pascal Tonometer

Specific Instrument Pascal dynamic contour tonometer
Measures/Output Measures intraocular pressure by a method which reduces the effect of corneal properties on the measurement
Sample clinical use Glaucoma
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Pachmate Ultrasonic Pachymetry

Specific Instrument DGH pachmate
Measures/Output Total corneal thickness
Sample clinical use Glaucoma assessment, corneal disorders
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras

 

Tomey A-Scan and B-Scan Ultrasonography

Specific Instrument UD-6000a
Measures/Output A-Scan biometry and B-Scan eye cross-section/morphology
Sample clinical use Assessment for cataract surgery, posterior eye tumours, optic disc drusen
CF-1 mydriatic and CR-1 non-mydriatic fundus cameras
 